Anchor | ||||
---|---|---|---|---|
|
Warning |
---|
Important information for upgrade customers who already use Woodford
|
...
- In MobileTech Administration, choose select Tools > Launch Woodford.
- Enter the user name, and password to log on to Woodford.
- Choose Select OK.
- The Registered User window may display. If it does, enter your contact information in the window and choose select Register.
If the "New update is available" message is displayed, choose select Later.
- Choose Select Import and browse to the location where the MobileTech.woodford file was saved when you installed MobileTech Administration. For most users, the location of the Woodford file is C:\Program Files (x86)\Signature\MobileTech\Admin\Woodford.
In the Add Mobile Project window, select MobileTech x-xx-xxx.woodford and then choose select Open.
- In the Import Project window, for Type, select Standard User.
- Select Next
- Select Default in the App drop-down, otherwise manually enter Default as the New App Name.
- Select Next.
- Complete the following fields:
- Name
Accept MobileTech x-x-xx. - Priority
Accept the default "0", however, if you have more than one project for the same security role, the one with a higher priority is used. - Custom Version Identifier (Optional)
Leave blank or enter any descriptive text. This information displays in the Project Version column in the App Projects grid. You can edit the project properties to update this field if needed. - Roles
Mark MobileTech. If you are using the Inspection feature, mark Inspector.
- Name
- Select Save or Create.
- Publish the project.
...
- In MobileTech Administration, choose select Tools > Launch Woodford.
- Enter the user name, and password to log on to Woodford.
- Choose Select OK.
- The Registered User window may display. If it does, enter your contact information in the window and choose select Register.
If the "New update is available" message is displayed, choose select Later.
If you have an existing MobileTech project, you must deactivate the project before importing the new/updated project. Select the project and then select Deactivate from the top navigation.
Note - If you have already made customizations to MobileTech by using Woodford, you must reapply those customizations each time you upgrade MobileTech and the corresponding Woodford project.
- Re-enable any options that were enabled in Woodford. For example, if you are using Mobile Auditing (UseMobileAuditBackgroundSync=True), please be sure to re-enable the Woodford Auditing settings after importing a new Woodford project.
- Choose Select Import and browse to the location where the MobileTech.woodford file was saved when you installed MobileTech Administration. For most users, the location of the Woodford file is C:\Program Files (x86)\Signature\MobileTech\Admin\Woodford.
In the Add Mobile Project window, select MobileTech x-xx-xxx.woodford and then choose select Open.
Note If you are re-importing the same project version and are prompted to overwrite the existing deactivated project, choose select Cancel and then rename the existing deactivated project using Properties in the top navigation. Then import the project and choose select Create New in the window that displays and continue with the instructions below.
- In the Import Project window, select the Type as Standard User.
- Select Next.
- Select the App drop-down and select Default.
- Select Next.
- Complete the following fields:
- Name
Accept MobileTech x-x-xx. - Priority
Accept the default "0", however, if you have more than one project for the same security role, the one with a higher priority is used. - Custom Version Identifier (Optional)
Leave blank or enter any descriptive text. This information displays in the Project Version column in the App Projects grid. You can edit the project properties to update this field if needed. - Roles
Mark MobileTech. If you are using the Inspection feature, mark Inspector.
- Name
- Choose Select Save.
- An exclamation point icon displays next to the mobile project to indicate the project has not been published.
- Double-click the MobileTech mobile project.
- In the Navigation bar at the top, verify that the Publish Version displays 13.3. If it doesn't, use the drop-down to select this version to avoid sync issues.
- Choose Select Publish All.
- In the Select Projects window, verify that MobileTech is marked and then select OK.
- Unmark the option to be notified when Woodford updates are available. In Woodford, choose select Settings and unmark the Check for updates on startup checkbox.,
- Click Save.
- Publish the project.
...