  1. To edit an inspection item, choose the item and then choose Edit Item to open the Inspection Item window.The buttons to the right of the Inspection Item Group: 

    Expand


    • Choose "+" to add new Inspection Item Group title
    • Choose "-" to remove the Inspection Item Group title
    • Choose "..." to edit the Inspection Item Group title
  2. On the Configuration tab, the Inspection Item Group defines the location of the inspection item in the report.  Choose the Inspection Item Group drop-down to choose a different group (location).
  3. The information entered in the following fields display on the completed report: 

    Expand


    • Inspection Item Title
    • Inspection Description
    • System Effect
    • Recommendations
  4. Choose the + icon to the right of Inspection Item Group to open the Inspection Item Configuration window. 

    Expand

     

  5. Enter the failed text to display in the Inspection Failed Text field. The text displays the sum of all setpoint select rule failures from all devices. Note that many setpoint rules may apply to each device. 

    Expand

  6. Enter the passed text to display in the Inspection Passed Test field. 

    Expand

  7. Choose the Expression tab to define the criteria that expresses a failed condition.The screenshot example expression as entered can be described as "When the CoolSetpointOcccupied is greater than 76 more than 10% of the Inspection report DateRange. The Default is One month.The available Numeric aggregation types for the DateRange aggregation are: 

    Expand


    • First - The first collected value.
    • Last - The last collected value.
    • Sum - The sum of all collected values.
    • Avg - The average of all collected values.
    • Min - The minimum of all collected values.
    • Max - The maximum of all collected values.
    • Delta - The difference between the minimum and maximum of all collected values.
  8. The available Boolean or True False aggregation types for the DateRange aggregation are:

    • OccurrenceCount - The number of true occurrences.
    • ChangeCount - The number of true false occurrence changes.
    • PercentActive - The percentage of time where the expression is true.
    • TotalDuration - The total duration of time where the expression is true.
  9. Choose the Filter tab to open the Filter Criteria window. 

    Expand

  10. Choose Edit to create or edit a filter.
  11. In the Edit Criteria window, choose the criteria that defines when the expression will be applied.
  12. Choose OK.
  13. Choose the Devices tab to open the Devices window. If the Inspection Item Rules were created from more than one profile or a profile exists in more than one agent, the list of devices could be extensive.Buttons on this window:  

    Expand


    • Edit Filter - Choose to create or edit a filter.  The filters are based on the tags applied to the agents and/or devices.
    • Clear Filter - Clears the filters
    • Ungroup Devices - Choose to remove the agent hierarchy and list only the devices.
  14. Choose the drop-down to the left of the Agent name to display the devices within the list.
  15. Choose the check box to the left of the Agent name to select all devices under the Agent or you can choose individual check boxes. 

    Expand

  16. Choose OK.

...

  1. Choose the Occupied Runtime Tab. 

    Expand

  2. In the Occupied Hours section, define the day(s) and time that will be considered Normal runtimes. Any operation of objects selected in the Objects to Monitor pane will be compared to these hours. Any operation outside these times will be considered as Unoccupied Operation. The default days are marked Monday to Friday with the Time Period from 8:00 AM to 5:00 PM.
  3. To edit this information, you can mark/unmark the days of the week.
  4. To edit the Time Period, choose the day and then choose the Edit button.
  5. In the Time Range window, you can either enter the start time and end time or you can drag the slider ends to the appropriate time. 

    Expand

  6. Choose OK.
  7. In the Objects to Monitor section, choose New Item.
  8. In the Browse window, choose either a: 

    Expand

    Image Removed

  9. Single or small group of occupancy references - If you choose this method, you may continue to add additional single occupancy references from other devices to the list. You may also repeat this process to add a selected group of space temperature objects. OR
  10. Profile group of occupancy references - If you choose this method, the provided group of objects will be drawn from the profile selected.

    NoteIf your database of agents contains other objects with the same object name, ALL of those objects will also be included. Use the filtering tool to limit the list of returned occupancy references to one agent. 

    a device object that reflects the Occupancy status of the equipment included in the Inspection Items. The Occupied Runtime tool is intended to calculate the run time hours using an occupancy reference from a single device.

  11. Choose OK to return to the Occupied Runtime main view.
  12. If no Occupancy Objects are selected, the Inspection report will not include a Building Metrics Occupancy section. The DateRange used is the current month. 

    Expand

  13. Choose OK to close the Edit Inspection Report window. The Inspection report displays with the information that you have set up.

...